Omron R88D-KN series User Manual page 458

G5-series with built-in ethercat communications linear motor type
Hide thumbs Also See for R88D-KN series:
Table of Contents

Advertisement

Appendicies
Disable operation option code
605C hex
5 to 0
Range
Size
2 bytes (INT16)
• This object sets the operation of the G5-series Servo Drive during deceleration and after stop,
following the Servo OFF (Disable operation) state.
Description of Settings
Set value
-5
Immediate Stop
Immediate Stop Force = 3511 hex
-4
Immediate Stop
Immediate Stop Force = 3511 hex
-3
Dynamic brake operation
-2
Free-run
-1
Dynamic brake operation
0
Free-run
*1 Decelerating is the time between when the motor is running and when the motor speed reaches
30 mm/s or less. Once the motor reaches 30 mm/s or less and moves to the after-stop status, subsequent
operation is based on the after-stop status regardless of the motor speed.
*2 "Immediate Stop" means that the motor stops immediately by using controls while the servo is kept ON. The
force command value at this time is restricted by the Immediate Stop Force (3511 hex).
*3 When the error is cleared, a process which makes the Position demand value follow the Position actual value
comes into effect. To operate in cyclic sync mode (csp) after the servo turns ON, reset the command
coordinates in the host controller and then execute the operation. The motor may move suddenly.
Precautions for Correct Use
Precautions for Correct Use
• Position control is forced into operation during deceleration and after the motor has stopped
(during servo OFF). The internal position command generation process is also forced to stop.
• If an error occurs while the servo is OFF, operation will follow the Fault reaction option code
(605E hex).
• If the main power supply turns OFF while the servo is OFF, the Shutdown option code
(605B hex) will be followed.
A-58
Unit
Access
*1
Decelerating
Deceleration method
*2
*2
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
1
Default
RW
PDO map
After stopping
Error
Operation after stopping
*3
Free
Clear
*3
Dynamic brake operation
Clear
*3
Free
Clear
Dynamic brake operation
*3
Clear
*3
Dynamic brake operation
Clear
*3
Free
Clear
All
Attribute
B
Not possible
Error
*3
Clear
*3
Clear
*3
Clear
*3
Clear
*3
Clear
*3
Clear

Hide quick links:

Advertisement

Table of Contents
loading