Electrolux EYL85066BT User Manual page 14

Table of Contents

Advertisement

14
www.electrolux.com
NOTE: Make sure the o-ring is clean and
on the correct position when putting the
terminal block on.
To connect the mains water supply
Connect the mains water supply to the
water inlet by using a 15MM push t(not
supplied). DO NOT use excessive force
when making the connection.
NOTE:
It is essential that all pipe work is ushed
through to remove debris and swarf that
could otherwise damage the unit.
A proper sealant should always be used
to seal around the incoming pipework to
prevent water entering the wall.
If entry is from the back, the nut of the
compression tting will be partially behind
the surface of the wall. This area MUST
be left clear when plastering and tiling
around the pipework in order to make the
nut accessible for future adjustments(Fig. 5).
Fig. 5
21mm
To check the water supply leak
Turn on the mains water supply and check
for leaks in the pipework connection to the
shower.
NOTE: At this stage no water can ow
through the unit.
5.3
Electrical wiring connection
To select the wiring terminal position
This Electrolux shower heater has 2 wiring
terminals and 2 earthing terminals shown
as Fig. 6. You can choose the proper
terminals when connecting the wiring.
Fig. 6
Warning
only one of the terminal blocks is to used
for the supply cable connection, the other
terminal block is not to be used.
To do the wiring connection
Route the cable into the shower unit for
connection to the terminal block as follows:
Earth:
cable to terminal marked
Neutral:
cable to terminal marked
Live:
cable to terminal marked
Important!
When connecting the cable fully tighten the
terminal block screws and make sure that
no cable insulation is trapped under the
screws. Loose connections can result in
cable overheating.
Wiring
terminal.
Earthing terminal

Hide quick links: