Advertisement

S E R V I C E M A N U A L
GAS WATER HEATER
GWH-275 R N
GWH-350 R N
EHT Haustechnik GmbH
Gutenstetter Straße 10
90449 Nürnberg
GERMANY

Advertisement

Table of Contents
loading

Summary of Contents for Electrolux GWH-275 R N

  • Page 1 S E R V I C E M A N U A L GAS WATER HEATER GWH-275 R N GWH-350 R N EHT Haustechnik GmbH Gutenstetter Straße 10 90449 Nürnberg GERMANY...
  • Page 2 Content Main features Function diagram Technical data Parts Operation Installation, Comissioning, Maintenance Recovery and disfunction How to ...
  • Page 3 Main features Piezo electric ignition Aluminium coated copper heat exchanger Pilot cut-off by ignition knob Automatic water flow adjuster Thermocouple safety mechanism...
  • Page 4 Operating diagram GWH-275 R N...
  • Page 5: Technical Data

    Technical data GWH-275 R N GWH-350 R N Type 2H3+ 2H3+ Output 7.0 to 19.2 kW 9.4 to 24.4 kW Type max. ∆T 54 K 54 K DHW flow 2.4 to 11.0 3.5 to 14.0 ltrs/min ltrs/min min. water press.
  • Page 6 Function diagram Flue gas safety thermostat Flue hood Heat excanger Combustion chamber Thermocouple Burner Ignition electrode Gas valve Water switch...
  • Page 7 Parts Flue gas safety thermostat Flue hood Heat excanger Combustion chamber Thermocouple Burner Ignition electrode Gas valve Water switch...
  • Page 8 Operation OVERVIEW GWH OFF Ignite the pilot flame min. power mode max. power mode Safety function...
  • Page 9 GWH OFF...
  • Page 10 Ignite the pilot flame Push and turn...
  • Page 11 min. power mode...
  • Page 12 max. power mode...
  • Page 13 Safety function Flue gas saefty thermostat Thermocouple...
  • Page 14 Fixing, Installation, Maintenance OVERVIEW Before the installation Fixing the appliance Installing – Gas connection Comissioning Maintenance...
  • Page 15 Before the installation Make sure, that the supply gas class is the same as on the type plate. Make sure that the max. water pressure does not exceeds 10 bar. If necessary install a pressure reducer.
  • Page 16: Fixing The Appliance

    Fixing the appliance In a suitable place on the wall following the instruction given, mark the holes where the plugs are to be inserted to fix the geater to the wall. Mark the position of the appliance‘s water inlet and outlet.
  • Page 17 Installing - Gas connection...
  • Page 18 Comissioning Before connecting up the appliance again, it is necessary to purge the water and gas pipe work thoroughly, in order to remove filings and other waste material. Fit the appliances onto the plugs and tighten the screw to fix the appliance to the wall. Then connect the gas intake to the appliance, ensuring that the seal is in place.
  • Page 19 Maintenance ATTENTION : Do only use original ELECTROLUX spare parts.
  • Page 20 Maintenance Make sure that the GWH is cooled down. Turn off the gas supply. Dismount the flue hood. Dismount the burner. Clean the heat exchanger with a brush. Clean the burner. Clean the pilot.
  • Page 21 Recovery of disfunction OVERVIEW Decrease of water temperature Increase of hot water flow Decrease of hot water flow No pilot flame ignition No keep up of the pilot flame Out of operation after a while Long time til holding safety valve...
  • Page 22 Decrease of water temperature Decrease of hot water temperature? too high goto: Water flow Water flow Increase is OK? of hot water flow too low goto: Decrease of hot water flow supply Gas filter Clean main gas filter. pressure is free? is OK ? Contact the gas supplier.
  • Page 23 Increase of hot water flow Increase of hot water flow? Water We recommend to supply install a pressure pressure reducing valve. is OK ? Change the water valve.
  • Page 24 Decrease of hot water flow Decrease of hot water flow? Water tub Clean the water tub. is free ? Water supply Contact the water pressure supplier. is OK ? Cold water Clean the cold water strainer is strainer free ? Heat Clean or change the exchanger...
  • Page 25 No pilot flame ignition No pilot flame ignition? Ignition Ignition Check ignition Change the ignition spark electrode electrode. electrode. visible? is OK ? Change piezo igniter. supply Gas filter Clean the gas filter. pressure is free ? OK ? Contact the gas supplier.
  • Page 26 No keep up of the pilot flame No keep up of the pilot flame? Flue gas Change the flue gas thermostat thermostat. is OK ? Thermo- Change the couple is thermocouple. OK ? Electric Change the electric gas valve gas valve. is OK ? Check electric wires and connections.
  • Page 27 Out of operation after a while Out of operation after a while? Flue gas Clean the flue gas pipe is pipe. free ? Heat exchanger Clean the heat fins are exchanger fins. clean ? supply Contact the gas pressure supplier. is OK ? Flue gas Change the flue gas...
  • Page 28 Long time til holding safety valve Long time until holding the safety valve? Pilot jet is Clean the pilot jet. free ? supply Gas filter Clean the gas filter. pressure is free ? is OK ? Contact the gas supplier. Pilot gas Change the pilot gas filter is...
  • Page 29 How to ... OVERVIEW ... check the gas supply pressure ... check the gas filter ... check the burner pressure ... change the pilot gas filter ... check the flue gas thermostat ... check the thermocouple ... check the electric gas valve ...
  • Page 30 How to check the gas supply pressure Supply pressure Natural gas 20 mbar Differential pressure gauge Butane 30 mbar Measuring range min. 100 mbar Propane 37 mbar Crosstip screwdriver PH 2...
  • Page 31 How to check the gas filter Always use new packings.
  • Page 32 How to check the burner pressure GWH-275 R N GWH-350 R N Natural gas 16,4 mbar 14.2 mbar Differential pressure gauge Butane 27.6 mbar 27.6 mbar Measuring range min. 100 mbar Propane 35.7 mbar 35.0 mbar Crosstip screwdriver PH 2...
  • Page 33 How to change the pilot gas filter Spanner across flat 8 Crosstip screwdriver PH 2...
  • Page 34 How to check the flue gas thermostat Check for continuity. Multimeter...
  • Page 35 How to check the thermocouple 15 to 20 mV Crosstip screwdriver PH 2 Spanner across flat 8 Spanner across flat 11 Multimeter...
  • Page 36 How to check the electric gas valve Dismount the electric gas valve for checking. The electric magnet must hold the disc piston against the spring force. Crosstip screwdriver PH 2 Spanner across flat 8 e.g. 1.5 V Battery...
  • Page 37 How to clean the cold water strainer...
  • Page 38 How to clean the pilot jet Release the pilot. Remove the pilot and the jet. Blow through the pilot pipe to remove the dirt accumulated inside. Undo the jet and clean it by brushing its surface gently. Then blow through the hole. Replace the pilot, ensuring that the seals are properly fitted.
  • Page 39 How to check the ignition electrode Visual examination during piezo ignition. Is no spark visible close the gas cock, unplug the ignition wire and ignite about the ignition wire against a metal part of the appliance. If a spark is visible now use a new ignition electrode.
  • Page 40 How to change the piezo igniter Dismount the spring ring on the gas valve axis. Dismount the 3 retaining rings. Change the piezo igniter unit. Screw driver Retaining pliers...