Installation Procedures - Patton electronics 571 User Manual

100base-t (cat-5) surge protectors
Hide thumbs Also See for 571:
Table of Contents

Advertisement

3.1.2 BARRIER APPLICATION (MODEL 581)
The Model 581 is a more robust protector than the Model 571, and
is designed for use as a barrier protector on LAN equipment in campus
networks. Applications include cable runs between buildings, cable
runs between floors on multi-story structures, and as a higher capacity
replacement for the Model 571.
Model 571 or 581
Local Hub
Model 571 or 581
Figure 2. A typical barrier application for the Patton Model 581.
The Model 581 is also well suited for use in severe lightning areas,
heavy industrial environments, and installations with heavy machinery
in the direct vicinity of sensitive LAN equipment and cabling. Figure 2
(above) shows a typical application for the Model 581. For best results,
the braided grounding strap on the Model 581 should be attached to the
grounded metal frame of the device being protected. When installation
is made at a barrier, such as an external wall, the braided strap should
be connected to a nearby electrical ground.

3.2 INSTALLATION PROCEDURES

In order to operate as designed, the Model 571 and 581 must be
connected correctly to your Cat-5 network. Please read all the
instructions below and follow them carefully.
Connection of the Model 571 or 581 to an I/O Port
1. Turn off equipment power and unplug (disconnect) the existing
connection between the UTP cable and the equipment's I/O port.
Electrical Panel
Model 571 or 581
Model 581
4
Exterior Wall
To other
bldg. or
floor