Connection of the Model 581 at a Barrier (Wall, Bldg Entrance, etc.)
1. Disconnect the UTP cable from the wall jack or patch panel jack.
2. Install the Model 581 between the UTP line and the jack. This
installation requires a straight through Cat-5 patch cable with
modular RJ-45 connectors (supplied with unit).
Note: The Model 571/581 provides bi-directional clamping
protection. Therefore, the network and equipment cables may be
connected to either end.
.
3. Locate an electrical ground nearest the jack. Often this will be on
an electrical panel or subpanel. If you cannot locate a nearby
electrical ground, contact Patton Technical Support at: (301) 975-
1007; http://www.patton.com; or, support@patton.com to
discuss an alternative grounding solution.
4. Connect the braided ground strap directly to the electrical ground
you have located. The best way to make this connection is to
attach the braided metal strap to a metal panel or wallplate screw
using a hex nut or screw.
Caution: Surge energy may run both directions on the ground
strap. To provide the best protection, it is essential that the ground
strap on the Model 581 be connected to an electrical ground.