Removing Deployment Errors - HP FlexFabric 12900 series Troubleshooting Manual

12900 series modular data center core switch
Hide thumbs Also See for FlexFabric 12900 series:
Table of Contents

Advertisement

Information described in
Product serial numbers.
Technical support registration numbers (if applicable).
This information will help the support engineer assist you as quickly as possible.
The following is the contact of HP Support for networking products:
http://www.hp.com/networking/support

Removing deployment errors

Use the deployment checklist in
stage. Select items that are suitable for your site.
Table 2 Deployment checklist
Question
Environment and card
hardware status
Is the switch temperature at
least 20°C (68°F) lower
than the warning
temperature threshold?
Are the fan trays operating
correctly?
Are sufficient power
supplies installed and are
they operating correctly?
Are the LEDs all displaying
correct statuses?
Are all cards operating
correctly?
"General
guidelines."
Table 2
to eliminate issues that might be introduced at the deployment
Command or method
display environment
display fan
display power
Visually check the RUN LED
and alarm LED on each card
display device
9
Result
Remarks
Make sure the temperature
□OK
of the switch is 20°C (68°F)
□Not OK
lower than the warning
□Not related
temperature threshold.
□OK
Make sure the fan trays are
□Not OK
operating correctly.
□Not related
Make sure the following
conditions are met:
You have installed
sufficient power supplies
□OK
to provide power
□Not OK
redundancy.
The power supplies are
□Not related
operating correctly. The
display power
command shows that
their state is Normal.
□OK
Verify that the RUN LED
□Not OK
flashes slowly, and the
alarm LED is off.
□Not related
Make sure all cards are
operating correctly.
All service cards are in
□OK
Normal state.
□Not OK
The active MPU is in
□Not related
Master state.
The standby MPUs are in
Standby state.