T1/E1 DACS Administrators' Reference Guide

Running Since Last Boot (sysUpTime)

This SNMP variable represents the time since the network management portion of the system was last re-ini-
tialized (see figure 35 on page 97).

System Manager (sysContact)

This SNMP variable represents the textual identification of the contact person for this managed node, which
may include information on how to contact this person as defined by specification RFC1213.MIB (see
figure 35 on page 97). The maximum length of this field is 256 octets.

Box Name (sysName)

This is "An administratively assigned name for this managed node. By convention, this is the node's fully-qual-
ified domain name." (RFC1213.MIB) (see figure 35 on page 97).

Physical Location (sysLocation)

"The physical location of this node (e.g., telephone closet, 3rd floor)." (RFC1213.MIB) (see figure 35 on
page 97).

Web Settings (boxBackgroundFlag)

The following options are available:
disableGraphics(0)—When this option is selected, graphics on WWW pages will not be displayed. This
results in faster page display times, but may make it more difficult to navigate WWW sites that rely heavily
on graphics.
enableGraphics(1)—When this option is selected, graphics on WWW pages are displayed.
disableWeb(2)—When this option is selected, access to the WWW pages is denied for everyone.

Monitor Privilege (boxMonitorPrivilege)

Specifies the privileges given to the monitor user. Privileges can be removed or additional write access can be
given beyond read-only access. The following options are available:
none(0)—The monitor user can not log in.
read-only(2)—This is the default setting. The monitor user can view but not change any parameters. Mon-
itor can not view passwords.
writeUser(18)—Not supported.
writeUserlp(50)—The monitor user can change all parameters—except passwords— IP links.
writeUserlpWan(114)—The monitor user can change all parameters—except passwords— IP, and T1/E1.
writeUserlpWanSystem(242)—The monitor user can change all parameters—except passwords— IP, T1/
E1, System, and System Log links.
writeUserlpWanSystemUpload(498)—The monitor user can change all parameters—except passwords—
IP, T1/E1, System, and System Log links. The monitor user can also load firmware updates into the DACS.