4 • Alarms
MinorSelfClearing(3)—Generate a minor alarm that automatically clears after a fixed period of time. If the
alarm condition has not ceased, the alarm will be automatically cleared, but another alarm will be immedi-
ately generated. If the alarm condition has ceased, the alarm will be automatically cleared after the same
fixed period of time.
MajorSelfClearing(4)—Same as MinorSelfClearing(3) except that it is a Major alarm instead of Minor.
Note
To set an alarm, click on the drop-down menu for the desired alarm item, choose the new setting followed by
clicking on Submit Query.
36
For maximum application flexibility, the administrator shall choose
which constitute major or minor alarm. Some examples of typical
major and minor alarms include:
- Box: Over Temperature—Major Alarm
- WAN 1: Red Alarm—MajorSelfClearing
- WAN 1: Yellow Alarm—MinorSelfClearing
T1/E1 DACS Administrators' Reference Guide
Modify Alarms—Configuring alarm severity levels