Switch S3-5: RS-232 Initiation of Local Loopback Test
The setting for switch S3-5 determines whether or not the Model
1065 local analog loopback test can be initiated by raising pin 18 on
the RS-232 interface.
S3-5
Setting
On
RS-232 initiation enabled
Off
RS-232 initiation disabled
Switch S3-6: RS-232 Initiation of Remote Loopback Test
The setting for switch S3-6 determines whether or not the Model
1065 remote digital loopback test can be initiated by raising pin 21 on
the RS-232 interface.
S3-6
Setting
On
RS-232 initiation enabled
Off
RS-232 initiation disabled
Switches S3-7 and S3-8: Anti-stream Control
Switches S3-7 and S3-8 are set in combination to determine the
time out period for the Model 1065 Series' anti-stream control timer.
S3-7
S3-8
Setting
Off
Off
Disabled
Off
On
12.5 seconds
On
Off
50.0 seconds
On
On
12.5 seconds
11
4.0 INSTALLATION
The Model 1065 operates in four twisted pair topologies:
2-wire/point-to-point, 2-wire/multipoint, 4-wire/point-to-point, and
4-wire/multipoint. In each of these topologies, the twisted pair wire
must be 19 - 26 AWG "dry", unconditioned metallic wire (see Appendix
C for wire recommendations). Dial-up analog circuits, such as those
used with a standard Hayes-type modem, are not acceptable. The
twisted pair may be shielded or unshielded. Both types yield favorable
results.
The Model 1065 offers an RJ-45 jack for its twisted pair line con-
nection. Figure 4 (below) shows the location of these interfaces on the
rear panel of the Model 1065 Series. Connect the wire to each Model
1065 Series as described in the instructions that follow the illustration.
The "+" and "-" indicators are for reference only.
Figure 4. Model 1065 rear panel.

4.1 TWO-WIRE INSTALLATION

When communicating over a single twisted pair circuit, the Model
1065 operates half duplex: that is, it transmits in only one direction at
a time. This method of operation is effective for both point-to-point and
multipoint applications.
In single pair point-to-point applications, you will need a pair of
Model 1065s for each circuit—one at each end of the single pair wire.
In single-pair multipoint applications you will need three or more Model
1065 units. These can be connected using a star topology, although a
daisy chain topology is usually used.