Configuration Switch Set "S2" - Patton electronics Model 1065 User Manual

Industrial synchronous & asynchronous short range modem
Table of Contents

Advertisement

Switch S1-8: Carrier Control Method
The setting for switch S1-8 determines whether the carrier is "con-
stantly on" or "controlled by RTS". This setting allows for operation in
switched carrier, multipoint and/or hardware handshaking applications.
S1-8
Setting
Off
Constantly on
On
Controlled by RTS

3.3 CONFIGURATION SWITCH SET "S2"

The DIP switches on S2 set word length, extended signaling rate,
RTS/CTS delay, V.52 and V.54 diagnostic test and 2- and 4-wire opera-
tion.
S2 SUMMARY TABLE
Position
Function
S2-1
Word Length
S2-2
Word Length
S2-3
Extended Signaling Rate
S2-4
RTS/CTS Delay
S2-5
RTS/CTS Delay
S2-6
2-Wire/4-Wire
S2-7
2-Wire/4-Wire
S2-8
V.54
Switches S2-1 and S2-2: Word Length
Switches S2-1 and S2-2 are set in combination to determine the
word length for asynchronous data, including the start and stop bits.
S2-1
S2-2
Setting
Off
On
8 bits
On
On
9 bits
Off
Off
10 bits
On
Off
11 bits
Factory Default
Off
}
10 bits
Off
Off -2.5% to 1%
On
}
7 ms
On
On (4-Wire) FDX
Off (4-Wire) FDX
Off V.54 Enabled
7
Switch S2-3: Extended Signaling Rate
The setting for switch S2-3 determines the range of variability the
Model 1065 Series "looks for" in asynchronous data rates (i.e., the
actual variance from a given frequency level the Model 1065 Series will
tolerate).
S2-3
Setting
Off
-2.5% to +1%
On
-2.5% to +2.3%
Switches S2-4 and S2-5: RTS/CTS Delay
The combined settings for switches S2-4 and S2-5 determine the
amount of delay between the time the unit "sees" RTS and when it
sends CTS. Options are no delay, 7 ms and 53 ms.
S2-4
S2-5
Setting
On
On
7 ms
Off
On
53 ms
On
Off
No delay
Off
Off
No delay
Switch S2-6 & S2-7: 2-Wire/4-Wire Mode Selection
The setting for switch S2-6 and S2-7 determines whether the
Model 1065 Series is operating in 2-wire or 4-wire mode.
S2-6
S2-7
On
On
On
Off
Off
On
Switch S2-8: V.54 Loopback Test Enable
This switch enables or disables V.54 looping in the Model 1065.
S2-8
Setting
Off
V.54 Normal Operation Enabled
On
V.54 Testing Disabled
Setting
4-wire (half duplex)
4-wire (full duplex)
2-wire (half duplex)