Kemppi FastMig MSF 53 Operating Manual page 20

Hide thumbs Also See for FastMig MSF 53:
Table of Contents

Advertisement

Memory functions (15)
Storage of settings
The memory functions can be used to record useful welding values in the memory. There are
ten different memory locations: 0 ... 9.
In addition to welding values (wire feed speed, welding voltage), function options such as
2T/4T, Creep Start, and Crater Level are recorded in the memory.
Storage in memory is performed as follows:
1. Press the MEMORY button twice; the SET light begins to flash if the channel is not in use. If
the channel is in use, the light remains lit. N.B.! If the memory is empty, press the MEMORY
key once to get in SET mode.
2. Select the desired memory channel with the CH key.
3. Make the settings and store them in the memory by pressing the SAVE button.
4. Press the MEMORY key twice. Notice that the ON light is lit.
5. Begin welding.
If you wish to change some values, the light must be switched from the ON setting to the SET
setting to enable you to select the required parameters. Press the SAVE button to complete
the procedure. It is also possible to save the parameters of the current weld by pressing SET
when the memory function is in OFF status (all lights off ). The channel can be cleared by
pressing MEMORY and the CH button simultaneously in SET mode.
Use of stored settings
1. Press the MEMORY button.
2. Select the memory channel via the CH button.
3. Begin welding.
The Ch remote function enables selection of memory channels via the selection controller
located on the gun. The function is activated by pressing buttons 17 and CH simultaneously.
When the CH-remote is activated the light in remote control or in gun control starts to flash.
EN
Synergic 1-MIG or FR-MIG welding (9, 11)
In Synergic 1-MIG welding, the optimal welding parameters for the welding wires and gas
used are recorded in the unit. The welding is controlled by adjusting the welding power and
arc length.
Synergic FR-MIG process is meant for root bass welding. Welding parametres and shape of
short circuit responce are optimized for root bass welding.
Welding arc/programme selection:
Before commencing welding, a welding arc/programme suited to the welding wire and gas
used must be chosen from the instructions on the inner surface of the MSF door.
Arc selection is activated by pressing button No. 9 for >1 second. In this case, displays 2 and
8 begin to flash and the material group is selected from the left-hand potentiometer and the
welding arc/programme for the material group in question from the right potentiometer; see
the enclosed table.
The selected programme is immediately recorded in the memory. To get back to normal status
press ON/OFF (1) key, or Synergic PROGRAM button (9).
Use of a selected welding arc/programme:
Select the relevant welding process with the 1-MIG selection button (11). Check that the
welding arc/programme corresponds to the welding wire and shield gas in use. The check
is performed by briefly pressing the Synergic PROGRAM button (9), after which the displays
show the material group and the programme number. Consult the above-mentioned table for
the wire type and gas that correspond with the programme number.
Set the desired welding power via potentiometer 14 and the arc length via potentiometer 16.
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fastmig msf 57Fastmig msf 55

Table of Contents