TO TURN ON THE HEATER
1. Turn on the valve on the gas supply cylinder.
2. Press and turn the variable control knob to PILOT position.
3. Press down the variable control knob and hold for 20 seconds. While
holding down the variable control knob, press the igniter button
several times until the pilot flame ignites. Release the variable control
knob 10 seconds after the ignition.
If a new tank has just been connected, please allow at least one
minute or more for the air in the gas pipeline to purge out through the
pilot hole, or simply do step 3.
. When lighting the flame make sure that the variable control knob is
continuously depressed while pressing the igniter button. Variable
control knob can be released after flame lit for 10 seconds.
The flame can be watched and checked from the peephole located on
the base of the burner.
If need small flame, turn the variable control knob to LO position.
4. Turn the variable control knob to LO position for 5 minutes or more
before turning the knob to desired temperature setting.
5. If the burner flame goes out accidentally or it is blown out by wind,
turn off the heater and wait at least 5 minutes or more to let the gas
dissipate before lighting again to avoid possible gas explosion. Repeat
steps 2 to 4.
1. The whole gas system, hose, regulator, pilot or burner should be
inspected for leak before use.
2. Check the hose assembly for sign of extreme abrasion, cuts or
wears. Suspected areas should be leak tested. If the hose leaks, it
must be replaced with a new one that conforms to local standard
codes.
3. Avoid twisting the flexible tubes and hoses.
4. Make sure the ventilation opening of the cylinder enclosure, control
compartment, burner and circulation air passageways of the heater
are free and clear of debris. If debris, spider or insect nests are
found, clean the holes with heavy-duty pipe cleaner or compressed
air.
5. Always keep a dry chemical fire extinguisher readily available.
6. For safety, always allow a 5minute complete shut off period before re-
lighting a hot heater.

OPERATION

WARNING
53