Gas connections on the appliance are leak tested at the factory prior to
shipment. Possible mishandling of the appliance during the shipment might
contribute to product integrity as a whole. A complete gas leakage test must
be performed again at the installation site. Please follow the procedure below
for leakage test.
Make a soap solution of one part liquid detergent and one part water. The
-
soap solution can be applied with spray bottle, brush or rag. Soap bubbles
will appear where a leak is present.
Make sure the control tap is in the "OFF" position on the control panel.
-
Turn on the gas supply and check for bubbles from the hoses and
-
connections. Presents of bubble means that a leak path is present.
If a leak is present, turn OFF the gas supply immediately, tighten any
-
leaking fitting carefully, turn gas again and recheck.
Never leak test while smoking.
-
TURN ON THE HEATER
1. Turn on the valve of the LPG Gas Cylinder completely.
2. Press and turn the control knob (counter-clockwise 90°) to position "PILOT"
3. Press down the control knob and hold for 30 seconds. While holding down
the control knob, press the igniter button several times until the pilot flame
alights. Keep to press in the way to give time to the thermocouple to keep
open gas circuit (30 seconds). Release the control knob. If pilot does not
keep alight, do the same procedure again.
Note:
If a new LPG Gas Cylinder has just been connected, please allow at least
-
one minute for the air in the gas pipeline to purge out through the pilot
hole.
When lighting the pilot flame make sure that the pilot light button is
-
continuously pressed down while pressing the igniter button. Pilot light
button can be released after the pilot flame lights.