Preparation:
You will need to purchase a LPG cylinder。You
need a suitable size LPG cylinder that can be
installed to the compartment.
You have to use pressure regulator with an outlet
pressure comply with the appliance category. The
flexible tube must be approved also.
Connect the hose to the hose connector in the
control box
Warning:
Always test the hose for leaks with soapy water at
Warning:
Never use the heater while it is raining, the glass tube would break when it
suddenly met water.
Always turn off the heater while there is a rain.
Never splash any liquid to the glass tube when the heater is working
The glass tube will be extremely hot when it is working, never try to touch
it and Keep the children away from the heater.
Always ensure the heater stands firmly, the glass tube may break if the
heater was fell down onto ground.
Never use the heater if the glass tube has any crack

LIGHTING INSTRUCTIONS

Check and ensure that an AA
battery is inside the ignition
chamber and has power.
Ensure the
anode(+) faces outside.
1.Ensure that the control knob is OFF. Slowly open
the gas cylinder valve.
2.Press and turn the control knob to LIGHT position,
push the igniter to generate spark while keeping
control knob in pressed position
3.Check for pilot flame through glass tube. If pilot
does not light, turn control knob to 'OFF' position
wait two minutes minimum and try again from the
start. Some attempts may be necessary.
4.If the pilot alight, keep control knob pressed for 15
seconds then turn the control knob to 'LOW'.
both of the ends.
5.For maximum heat
turn control knob to
'HIGH'.
6.To turn heater off,
turn control knob to
'OFF'.
7.Close the vlave of
the gas cylinder or the
regulator after use.