User Options; Access Control User Options - Paradox Digiplex EVO EVO48 User Manual

Paradox keypad user guide
Table of Contents

Advertisement

LCD
LED
LCD

7.6 User Options

Options [1] and [2]: Master Feature
[1]
When option
is OFF, the User cannot program other users into the system.
[1]
When option
is ON and option
access codes (P.I.N. only) and User Labels.
When both options
create or modify user access codes, User Options, User Access Control Options, Access
Card Numbers, User Labels and Area Assignments according to their own programming.
For example, if the Full Master User has access to area #1 and option
the Full Master user can only assign area #1 and option
Option [3]: Duress
[3]
When option
is ON, the Duress feature is enabled. This feature is used when
someone forces a user to arm or disarm an area(s). By entering a user access code
(P.I.N.) reserved for the Duress feature, the system will arm or disarm the area(s), and
then send a silent alarm to the monitoring station.
Option [4]: Bypass
[4]
When option
is ON, the Bypass feature is enabled. This feature allows the user to
deactivate zones when arming the area(s).
Option [5]: Arm Only
[5]
When option
is ON, the Arm Only feature is enabled. The user can arm assigned
areas with either a card or code, but cannot disarm. When the option is OFF, the user
can either arm or disarm assigned areas.
Option [6]: Stay & Instant Arm
[6]
When option
is ON, the Stay and Instant arm features are enabled. The user can now
Stay or Instant arm their assigned areas.
Option [7]: Force Arm
[7]
When option
is ON, the Force arm feature is enabled. The user can now Force arm
their assigned areas.
Option [8]: Area Access
[8]
When option
is ON, the keypad will permit access to all the areas assigned to the
user access code. When option
areas it controls. For example, the keypad is assigned area 1 only, and your user access
code is assigned areas 1 to 8. If the option is ON, you can access all eight areas from the
keypad. If the option is OFF, you can only access area 1.
By default all users can Regular arm the system.

7.7 Access Control User Options

Option [1]: Access Control
[1]
When option
is ON, the user can gain access to an access control door when Access
Control is enabled in the system. A user that is not assigned to any partition, but has the
Access Control option (Option [1]) enabled, can now gain access to an access control
door by entering a code # (P.I.N.) and then pressing the
option is OFF, the user cannot access an Access Control door.
Option [2]: Can Disarm with Access Card
[2]
When option
is ON, a User's Access Control card can unlock and disarm an armed
Access Control door. When option
17.
For option
User Options must be disabled (refer to section 7.6 on page 15).
[2]
is OFF, the user can program and modify user
[1]
[2]
and
are ON, the user has Full Master rights. The user can
[8]
is OFF, the keypad will only permit access to the
[2]
is OFF, follow the settings in option
[2]
to function in the ON position, option
[4]
(Bypass) only,
[4]
to other users in the system.
[
]
keypad key. When the
ACC
[8]
on page
[5]
"Arm Only" in the
EVO Systems 15