Water Coming From Chiller
The water may be normal condensation produced as a by-product of the chiller's refrigeration process. The
chiller can produce 8 to 10 gallons of condensation per day depending on the humidity of the ambient air.
Determine if the water is condensation or a possible leak.
1. If using chlorine or bromine as a pool / spa sanitizer, use a test strip in the water at chiller to determine if
sanitizer is present. If sanitizer is present, a leak may exist.
2. Deactivate chiller, leaving the filter pump on. After several hours, determine if water is still coming from the
chiller.
3. If the issue reoccurs, please contact AquaCal
on page 1.