Aquacal TropiCool TC500 Installation Manual page 23

Hide thumbs Also See for TropiCool TC500:
Table of Contents

Advertisement

Titanium ThermoLink
1. Reinstall front access panel.
2. Disconnect the plumbing to the chiller at connection unions (removal is counter-clockwise).
3. Allow water to drain completely from the chiller. Expect to see a lot of water drain out at
first, and then a small amount to continue to drain out over a long period.
4. After chiller is fully drained, reinstall front access panel.
5. Partially reconnect plumbing connection unions.
6. Winterizing is complete.
7. When ready to use chiller again, hand-tighten connection unions. Reconnect electrical
power, and set the operating mode on the chiller. Activate filter pump.
Cupronickel Tube in Tube Exchanger
1. Reinstall front access panel.
2. Disconnect the plumbing to the chiller at connection unions (removal is counter-clockwise).
3. Place a garden hose into the inlet side of the chiller; wrap a clean rag around the hose to
form a temporary seal.
4. Turn on the garden hose water supply.
5. Allow water to run through the heat exchanger for 2-3 minutes; fresh water should be seen
exiting the pool's out-port.
6. Place a garden hose into the outlet side inlet of the chiller; wrap a clean rag around the hose
to form a temporary seal.
7. Turn on the garden hose water supply.
8. Allow water to run through the heat exchanger for 2-3 minutes; fresh water should be seen
exiting the pool's in-port.
9. Place an air hose into the pool inlet of the chiller; wrap a clean rag around the hose to form a temporary seal.
10. Push all water from the water circuit using compressed air at approximately 50 psig. The residual water should
be forced out of the chiller pool outlet.
11. Allow compressed air to blow into the chiller inlet for at least 15-20 seconds after the water stops coming out.
12. Repeat process on the outlet side.
13. Partially reconnect plumbing connection unions.
14. Winterizing is complete.
15. When ready to use chiller again, hand-tighten connection unions. Reconnect electrical power, and set the
operating mode on the chiller. Activate filter pump.
®
Exchanger (with no Drain)
No Drain
Cupronickel
(Orientation
depends
on model)
Page - 20