Deactivate Time Delay - Aquacal TropiCool TC500 Installation Manual

Hide thumbs Also See for TropiCool TC500:
Table of Contents

Advertisement

CODE
CFO
dBP
dB5
DEL
DSC
dFd
FS2
JAO
LOC
TSC
Table 2 - Default Program Parameters Chart
3.5.b Deactivate Time Delay
The time delay should only be deactivated by qualified HVAC technicians for diagnostic convenience, and
must be re-activated prior to placing chiller back in service. Failure to reset time delay feature could result in
permanent damage to the compressor.
Press "Up" and
"Down" buttons
simultaneously
until CF1 appears.
Page - 11
DESCRIPTION
Call-Flex Options
Pool Dead-Band Differential
Spa Dead-Band Differential
Compressor Time Delay
Defrost Sensor
Defrost Delay
Flow Switch / Auto T-Stat
Switching Option
External Controller
Service Entry Point
Water Sensor
Press "Pool / Spa"
button until LOC
is displayed.
DEFAULT
VALUE
Set to off at the
0
factory.
Set at Factory. Do
not adjust.
Set at Factory. Do
not adjust.
0 = "OFF"
1 (4 minutes)
1 = "ON"
Factory
Set at Factory. Do
Calibrated
not adjust.
Factory
Set at Factory. Do
Calibrated
not adjust.
0 = "No Switch"
0
1 = "Enable
Switch"
0 = "No Controller"
2 = "Two Wire
0
Controller"
3 = "Three Wire
Controller"
50
00 - 99
Factory
Set at Factory. Do
Calibrated
not adjust.
Press "Up" or
"Down" to
passcode. Default
is "17".
RANGE
Press "Pool / Spa"
button once.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tropicool tc1000

Table of Contents