(49) Adjusting the needle thread clamp sensor
When the needle thread clamp support plate complete
clamp position (Caution 1., 2.) the clearance A toward the needle thread clamp
(Caution) 1. The needle thread clamping position is defined by pressing the
retrieval in the test mode I08 (IP-410). This position is defined where it is returned by one
step from the most advanced position.
2. According to the thread clamp specifications, the memory switch U69 may change.
S Type → → → → → 0
H Type → → → → → 1
A
Standard Adjustment
is withdrawn by 3 to 4 pulses from the needle thread
3.3 to 3.7mm
– 72 –
becomes 0.
key after origin
B