netvox ZB11C1 User Manual

netvox ZB11C1 User Manual

Motion detector with on/off switch and temperature sensor

Advertisement

Quick Links

ZigBee
TM
- Motion
Detector with On/Off Switch and Temperature
Sensor

User Manual

Motion Detector with On/Off Switch and Temperature
Sensor
Model: ZB11C1
20140317
FW V2.0
HW V1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZB11C1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for netvox ZB11C1

  • Page 1: User Manual

    ZigBee - Motion Detector with On/Off Switch and Temperature Sensor User Manual Motion Detector with On/Off Switch and Temperature Sensor Model: ZB11C1 20140317 FW V2.0 HW V1.0...
  • Page 2: Table Of Contents

    5-8. Infrared Sensor Detection and Report......................10 5-9. Movement Detection and On/Off Control....................10 5-10. Tamper Alarm............................. 10 5-11. Restore to Factory Setting...........................11 6. Home Automation Clusters for ZB11C1......................12 7. ZiG-BUTLER................................. 14 7-1. Join ZB11C1 into the network........................14 7-2. Bind ZB11C1..............................15 7-3.
  • Page 3 8. Related Netvox Devices............................20 9. Important Maintenance Instructions........................20...
  • Page 4: Introduction

    1. Introduction Netvox ZB11C1, an infrared motion On-Off light switch with the temperature sensor, acts as an End Device in ZigBee network. It does not perform permit-join function as a coordinator or a router for other devices to join the network.
  • Page 5: Product Appearance

    2. Product Appearance Indicator (Red/ Green) Binding Key Auxiliary Key Infrared Sensor Light Sensitivity Adjustor Sensor Sensitivity Adjuster Release Button...
  • Page 6: Specification

    3. Specification  Fully IEEE 802.15.4 compliant (ZigBee Pro) Utilizes 2.4GHz ISM band; up to 16 channels   Power supply: 2 x 1.5V AA batteries  Operating consumption: ≤ 45mA  Standby consumption: ≤ 100uA  Temperature Sensing Range: 0~60℃ ...
  • Page 7  Apply the double-sided tape: 1. Clean surface with isopropyl rubbing alcohol, wipe gently, and let dry. 2. Remove one-side liner. Press adhesive to the bottom of ZB11A1. 3. Remove the-other-side liner. Press to surface for 20 seconds.
  • Page 9: Setting Up Zb11C1

    5-2. Join the ZigBee Network After ZB11C1 is turned on, it will search for an existing ZigBee network and send a request to join the network automatically. While ZB11C1 is under the coverage from a coordinator or a router whose permit-join feature is enabled, ZB11C1 will be permitted to join the network.
  • Page 10: Binding

    A. While the device is in the network → the sleeping period is 5 minutes; it will wake up every 5 minutes to keep online. B. When it doesn’t find a network to join → ZB11C1 will go to sleeping mode. It will wake up every 15 minutes to search a network to join.
  • Page 11: Battery

    5-7. Battery ZB11C1 will send a low-power report to the ZigBee network when the operating voltage is lower than 2.1V by default. The related data:  Power configuration cluster (ID:0x0001)  Battery voltage attribute (ID:0x0020) The reporting voltage can be adjusted. There are 4 voltages for choosing: 2.4V/ 2.3V/ 2.2V/ 2.1V.
  • Page 12: Restore To Factory Setting

    5-11. Restore to Factory Setting To restore it to factory setting, please follow the steps: Step1. Press and hold the Auxiliary Key for 10 seconds. Step2. After the indicator shows fast green flashes, release the button to complete the restore.
  • Page 13: Home Automation Clusters For Zb11C1

    A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves. This table lists the clusters which are supported by ZB11C1. 1.End Point(s):0x01;0x02;0x03;...
  • Page 14 8-bit integer 0xff 0x0003 HWVersion Unsigned 0x00 – Read only 8-bit integer 0xff 0x0004 ManufacturerName Character 0 – 32 Read only netvox string bytes 0x0005 ModelIdentifier Character 0 – 32 Read only string bytes 0x0006 DateCode Character 0 – 16...
  • Page 15: Zig-Butler

    7. Important Maintenance Instructions  Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or moisture can contain minerals that corrode electronic circuits. In cases of accidental liquid spills to a device, please leave the device dry properly before storing or using.
  • Page 16: Bind Zb11C1

    FCC Statement: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.