13.5.4
Heating, RC or SH Group
Mode: Heat, Auto (at heating)
Temp: Selected desired temperature
Fan: HIGH, MED, LOW
Timer: Any
I Feel: On or Off
Control function
Maintains room temp. at desired level by comparing RAT or RCT to SPT.
o
(RT - SPT) [
c]
+2
+1
0
-1
-2
-3
ON
COMP
OFF
(WVL)
ON
HE1
OFF
ON
HE2
OFF
H/M/L
L
IFAN
OFF
ON
RV
OFF