Outdoor Unit - Electra DNG 18 Service Manual

Dng series
Table of Contents

Advertisement

OUTDOOR UNIT

UNIT DIMENSIONS
B
A
C
CAP.
A
B
C
5 Kw
610
795
500
6 Kw
680
900
705
9 Kw
860
900
705
10-13 Kw
970
900
705
14-16 Kw
1250
900
705
SEVERAL OUTDOORS INSTALATION
When installing several outdoors units please take into account
the air flow around the units and follow the minimum distance
suggestions as shown in the diagrams bellow.
Row Installation
intake
side
5cm
or
more
DISPOSAL OF OUTDOOR UNIT DRAIN WATER
In case of using a drain elbow, the unit should be placed on
a stand at least 3 cm high.
Install the hose with a downward to allow smooth flow of
draining water.
Use 16mm I.D. tube for drainage.
8
E
D
F
D
E
F
148
290
293
97
340
357
97
340
357
97
340
357
97
340
357
Air
25cm
or
more
CLEARENS AROUND THE UNIT
5 CM
5 CM
C M
1 0 0
Back to Back
Air
intake
side
20cm
0.5m
or
or more
more
1m
or
more
Front to Back
APPENDIX A
25 CM
Front to Front
5m or more
Air
intake
side
5m
or more