Fail condition:
0 sec - STAND-BY is turned ON
3 sec - STAND-BY, OPER, TIMER and FILTER are turned ON
When the timing reset test is completed, the next test will start automatically.
i.
STEP 8: MEMORY TEST (EEPROM)
The test purpose is to check if the memory is functioning correctly. The test result
is reported by using the STAND-BY and FILTER LEDS:
LED Indicator
STAND-BY LED
FILTER LED
AT THIS POINT THE SELF-TEST IS COMPLETED.
In order to terminate Self-Test mode the User can change the unit setting from COOL
Mode, LOW FAN to COOL Mode, MED FAN or to wait without using the remote control
for 60 sec.
Values of Sensors Temperature VS. Voltage (DC)
Temp.
Voltage
(°C)
(V)
-20
4,554
-19
4,529
-18
4,502
-17
4,475
-16
4.446
-15
4.417
-14
4.386
-13
4.354
-12
4.322
-11
4.287
-10
4.252
-9
4.216
-8
4.178
-7
4.14
-6
4.1
-5
4.059
-4
4.017
-3
3.974
-2
3.93
-1
3.885
0
3.839
1
3.792
Service Manual - DNG Series
Condition for LED to be ON
Test passed
Test failed
Temp.
Voltage
Temp.
(°C)
(V)
(°C)
2
3.744
24
3
3.695
25
4
3.646
26
5
3.595
27
6
3.544
28
7
3.492
29
8
3.439
30
9
3.386
31
10
3.332
32
11
3.278
33
12
3.223
34
13
3.168
35
14
3.113
36
15
3.058
37
16
3.002
38
17
2.946
39
18
2.89
40
19
2.833
41
20
2.777
42
21
2.722
43
22
2.666
44
23
2.61
45
Revision Y05-01
CONTENT
CONTROL SYSTEM
Voltage
Temp.
Voltage
(V)
(°C)
(V)
2.555
46
1.487
2.5
47
1.447
2.445
48
1.409
2.391
49
1.371
2.338
50
1.334
2.284
51
1.298
2.232
52
1.263
2.18
53
1.228
2.128
54
1.195
2.077
55
1.162
2.027
56
1.13
1.978
57
1.099
1.929
58
1.069
1.881
59
1.04
1.834
60
1.011
1.798
61
0.983
1.742
62
0.956
1.698
63
0.929
1.654
64
0.904
1.611
65
0.879
1.569
66
0.854
1.527
67
0.831
13-31