CONTROL SYSTEM
13.7.1
Dry, SH or RH group excluding P2000 model
Mode : Dry
Temp: Selected desired temp.
Fan:
Low (automatically selected by software)
Timer: Any
I FEEL: Any
Control function
Reduce room humidity with minimum Temp. fluctuations by operating in Cool Mode with low speed
IFAN and HE.
o
(RT - SPT) [
c]
+2
+1
0
10
-1
-2
LOW
IFAN
OFF
ON
COMP
OFF
& OFAN
ON
HE1
OFF
ON
HE2
OFF
ON
RV
OFF
Notes :
1) HP and Defrost protections are the same as in Cool Mode.
2) HEs are operated according to the room temp., in the same way as in
Heating for RH group .
3) IFAN is operating continuously at low speed.