Maintenance

The following inspections can be carried out by experienced employees. Only use genuine spare parts from
the unit manufacturer.
Cleaning the air filter
Push the lever to the left in order
to release the lug. Then push the
filter to the left and pull down to
remove.
- Clean the air filter in the
dishwasher at least once a
month and replace in unit after
drying.
- Air filters should be replaced at
least twice a year.
- Do not run the unit without an
air filter.
Replacing the door
seal
The door seal is fitted in a groove
on the cooking cabinet.
- Pull the old seal out of the
groove
- Clean the guide rail
- Insert new seal into the groove
(moisten the retaining lips with
soapy water)
- The rectangular part of the
seal must be seated fully in the
holding frame.
Cooking cabinet seals:
6 x 1/1 GN
6 x 2/1 GN
10 x 1/1 GN
10 x 2/1 GN
20 x 1/1 GN
20 x 2/1 GN
- 58 -
Replacing the halogen
lamp
First switch off the unit at the
mains.
- Cover the unit drain in the
cooking cabinet
- Remove the frame with glass
and seal
- Replace halogen bulb (article
no.: 3024.0201), do not touch
the bulb with your hands)
- Replace sealing frame as well
(article no.: 40.00.094)
- Screw the frame in place with
glass and seal
Article no.:
20.00.394
20.00.395
20.00.396
20.00.397
20.00.398
20.00.399