Mailing system Optimail 30 – Service documentation
S3: Settings
Security Device
S1: Reset HS-Loop
Steps: Settings
After opening the machine casing the HS-Loop can be reset.
(HS = housing security or also Casework Security)
After resetting the HS-Loop a zero reset is required.
S2: Authorize
Steps: Settings
The security device status changes from "Initialized" to "Authorized".
S3: Re-Authorize (Remote)
Steps: Settings
This feature is used to up date the customer's Zip code after they have changed addresses.
S4: Re-Initialize
Steps: Settings
This feature is used after withdrawing the meter from one customer and installing into a new customer.
S5: Echo
Steps: Settings
Refer to Test function section of this manual
S6: Secure-Echo
Steps: Settings
Refer to Test function section of this manual
S7: Withdraw
Steps: Settings
Withdrawing the meter transfers the remaining credit from the meter into the customers TDC account
and the USPS are informed electronically of the withdrawal.
The following data is deleted during this process:
-Cost Accounts
-Type of mail endorsements (but not standard endorsements)
-Type of mail statistics
-Class of mail (This may be a new USPS requirement in the future)
-Advertisements
-Gravity calibration value
-Zip code
-HP / LP warnings
-Shift position
S8: Self test
Refer to Test function section of this manual
S9: Lock out Security Device
The Security Device
resets the lock out. (Used only if manipulation is suspected and inform TDC to also lock the account)
Zac Moody/Andrew Nagel Revision June 2005 optimail30 service mode chapter2 (dealer)
Security Device
Reset HS-Loop
Security Device
Authorize
Security Device
Re-Authorize (Remote)
Security Device
Re-Initialize
Security Device
Echo
Security Device
Secure Echo
Security Device
Withdraw
changes the status manually from "Valid" to "Authorized" Performing a zero reset
FRANCOTYP-POSTALIA