75-00-00 8-2

MODIFICATION: RECONFIGURE FAN REVERSE

GENERAL, REFERENCES AND REQUIREMENTS
Task may only be performed by an organization or individual trained and entitled to carry out 'Line Maintenance'!
Secure gyroplane against unauthorized or unintended operation!
Engine cowlings must be removed, see
Fire wall must be removed, see
SPECIAL TOOLS AND CONSUMABLE MATERIALS
None
PRECAUTIONS AND SAFETY MEASURES
WARNING: Electrical shorting of the battery will produce high current with the risk of personal injury and
damage to equipment!
PROCEDURES
1
Disconnect battery according to
2
Detach fan reverse control unit (Fig. 1) from rear wall, cut fan reverse cable (Fig. 2) and remove fan reverse
control unit.
3
Isolate red wire 0,5 mm
wires (Fig. 2).
4
Crimp isolated butt connectors to wires and connect red/red and black/black (Fig. 3). Make sure connectors
are properly isolated to avoid shortcut.
5
Secure cable and connectors with cable ties according to Fig. 4.
6
Re-connect battery according to
7
Perform functional check.
PARTS LIST
Fig. Pos. Description
Replacement set Mast Attachment
MMM-CV-E_16-06-13
Manufacturer
Maintenance Manual
52-00-00 4-1
71-30-00 4-1
24-30-00
4-1, work steps 1 - 2.
2
2
and black wire 0,5 mm
with shrinking hoses and remove insulation of all 1,5 mm
24-30-00
4-1, work steps 2 - 1.