Remote Mount Wiring Diagrams; Combination Coil And Signal Cable Wiring Diagram - Emerson Rosemount 8732E Quick Installation Manual

Magnetic flowmeter system
Table of Contents

Advertisement

Quick Installation Guide
00825-0100-4662, Rev CC
December 2012
S
6
TEP
CONTINUED
Figure 16. Remote Mount Wiring Diagrams
NOTE
When using the Rosemount supplied combination cable, the signal wires for terminals 18
and 19 contain an additional shield wire. These two shield wires should be tied with the main
shield wire at terminal 17 at the sensor terminal block and cut back to the insulation in the
transmitter junction box. See Figure 17.
Figure 17. Combination Coil and Signal Cable Wiring Diagram
...
Coil Drive Cable
1 Red
2 Green 3 Shield
1 Red
2 Green 3 Shield
Rosemount 8732
Signal Cable
17 Shield 18 Black 19 White
17 Shield 18 Black 19 White
Cut Shield