Rosemount 8732
International Certifications
IECEx
E7 IECEx Flameproof
Certificate No: KEM 07.0038X
Ex IIC or Ex de [ia] IIC T6
without LOI (-50 °C  Ta  +60 °C)
with LOI (-20 °C  Ta  +60 °C)
V
= 250 V AC or 42 V DC
max
EF IECEx Flameproof
Certificate No: KEM 07.0038X
Ex de IIB or Ex de [ia] IIB T6
without LOI (-50 °C  Ta  +60 °C)
with LOI (-20 °C  Ta  +60 °C)
V
= 250 V AC or 42 V DC
max
NF IECEx Dust
Certificate No: KEM 07.0038X
Ex tD A20 IP66 T 100 °C
without LOI (-50 °C  Ta  +60 °C)
with LOI (-20 °C  Ta  +60 °C)
V
= 250 V AC or 42 V DC
max
Special Conditions for Safe Use (KEM 07.0038X):
Contact Rosemount Inc. for information on the dimensions of the flameproof joints. The
property class of the security screws which attach the flowtube or junction box to the
transmitter is SST A2-70.
Installation Instructions:
The cable and conduit entry devices and blanking elements shall be of a certified
flameproof or increased safety type, suitable for the conditions of use and correctly
installed. With the use of conduit, a certified stopping box shall be provided immediately
to the entrance of the enclosure.
N7 IECEx Type n
Certificate No: IECEx BAS 07.0062X
Ex nA nL IIC T4
with FISCO / FNICO output
Ex nA nL [ia] IIC T4
without LOI (-50 °C  Ta  +60 °C)
with LOI (-20 °C  Ta  +60 °C)
V
= 42 V DC
max
Special Conditions for Safe Use (x):
The apparatus is not capable of withstanding the 500V electrical strength test required
by Clause 6.8.1 of IEC 60079-15: 2005. This must be taken into account when installing
the apparatus.