Let off water by opening the dosage de-
vice at the discharge hose.
The rinse the dirt water reservoir with
clear water.
Emptying the fresh water tank
Release the coupling at the upper end
of the fill level display.
Lower the hose for the fill level display
into a suitable collector and drain off liq-
uid.
Engage the coupling on the appliance
again.
Transport
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport it.
Remove brushes to avoid damage to
the brushes.
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
Storage
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.
Maintenance and care
Danger
Risk of injury. Turn the program selection
switch to "OFF" and disconnect the mains
plug before performing any works on the
appliance. For BR...W Bp also turn the key
switch to "0" and press the emergency stop
switch.
Caution
Risk of damage to the appliance on ac-
count of water leakage. Empty the waste
water reservoir and the fresh water reser-
voir prior to performing maintenance on the
appliance.

Maintenance schedule

After the work
Caution
Risk of damage. Do not wash down the ap-
pliance with water and do not use aggres-
sive detergents.
Drain off dirt water.
Check the fluff filter, clean if required
Clean the outside of the appliance with
a damp cloth which has been soaked in
mild detergent.
Clean the vacuum lips and the wiping
lips, check for wear and replace if re-
quired.
Check the brushes for wear, replace if
required.
Charge battery if required.
Monthly
During long operating pauses: Carry
out refill charging for the battery.
Check battery pole for oxidation; brush
it if required and lubricate it using pole
grease. Ensure that the connection ca-
ble sits firmly.
Check the acid density of the cells if the
batteries are not maintenance-free bat-
teries.
Check the condition of the seals be-
tween dirt water reservoir and cover, re-
place if required.
Clean the brush tunnel (only BR model).
Remove the cover of the water inlet at
the cleaning head and clean the canal.
(only BR model)
In appliances with dosing equipment
(DOSE): Clean the detergent suction fil-
ter with clear water.
Only for BR/BD...W...: After 400 operat-
ing hours or once a year
Replace pump hose of the dosing pump.
Yearly
Have the prescribed inspection carried
out by the customer service.