MCAC-RTSM-201301-01

3.10 Trial run

Perform the trial run only after the outdoor unit has been powered on for over 12 hours.
Check that all valves should be opened before trial run.
Check the electric safety before trial run.
Do not perform compulsory operation in any way. (It is very dangerous if the protection device is
not active.)
Perform trial run only after all installations are finished.
When install the remote controller holder, the holder must be installed in a location suitable for
transmitting the signals of the remote controller to the indoor unit.
Use the remote controller or wired controller to let the unit run in the cooling mode. Inspect the
following items against the operation manual.
Check whether any vibration or abnormal sound occurs during the operation.
Check whether the air, noise and condensate generated by the unit affect the neighbours.
Check whether any refrigerant is leaked.
Check whether the connective copper pipes and drain pipes generate condensate due to
loose wrapping.
Open the air inlet grille of indoor unit to check whether any penetration or leak of water
occurs, especially at the drain stopper.