Panasonic WV-CS854A Operating Instructions Manual page 46

Combination camera
Hide thumbs Also See for WV-CS854A:
Table of Contents

Advertisement

BAUD RATE
Specifies the transmission speed (2 400, 4 800, 9 600, 19 200 bit per second) for the RS485 communica-
tion. The factory setting is 19 200.
DATA BIT
Specifies the number of data bits (7 or 8 bits) for the RS485 communication. The factory setting is 8.
PARITY CHECK
Specifies the parity check mode (NONE, ODD, EVEN). The factory setting is NONE.
STOP BIT
Specifies the number of stop bits (1 or 2 bits). The factory setting is 1.
X ON/X OFF
Specifies whether to apply flow control or not (NOT USE, USE). The factory setting is NOT USE.
WAIT TIME
Specifies the time to wait until retrying after confirming that no data is received from the controller. (OFF:
no transmission, 100, 200, 400, 1 000 ms).
ALARM DATA
Specifies alarm transmission mode depending on the protocol selected by the 8-bit DIP switch.
POLLING: Transmits the alarm data in response to requests from the controller.
AUTO 1: Transmits the alarm data each time an alarm signal is received in the camera.
AUTO 2 (Default): Transmits alarm data at intervals of at least 5 seconds.
DELAY TIME
Specifies the time to transmit the acknowledge request when communicating on a 2-line connection.
(OFF, 10, 20, 40, 100 ms) Default : OFF.
This menu appears only when a 2-line communication is used. Make sure to be 100 ms when connecting
the camera with the WJ-FS616 Video Multiplexer in a 2-line communication system.
The settings become effective with the closing of the SET UP MENU.
Note: Set the same parameters for the cameras, controllers and personal computers in an RS485 chain.