Panasonic WV-CS854A Operating Instructions Manual page 30

Combination camera
Hide thumbs Also See for WV-CS854A:
Table of Contents

Advertisement

Alarm IN/OUT (ALARM IN/OUT)
Move the cursor to ALARM IN/OUT, then press the CAM (SET) key.
ALARM I/O submenu appears.
Note: While the camera is in AF mode or the lens moves between
WIDE and TELE, alarm input may be ignored if several alarm
inputs are received in succession.
ALARM IN 1-4
Alarm input signals are supplied from external devices through
the ALARM IN connector to turn the camera to a preset position.
1. Move the cursor to ALARM IN 1* and select a preset position or
OFF by moving the joystick, then press the CAM (SET) key.
* Set ALARM IN 2, 3 and 4 in the same way as ALARM IN 1.
1 POSI, 2 POSI, 3 POSI, 4 POSI: Preset position. If an alarm input is received, the camera turns to a
preset position, then sends alarm output signal. Position number correspond to alarm input num-
bers (1-1, 2-2, 3-3 and 4-4).
B/W: Available for ALARM INPUT 4 only. The camera changes its mode from color to black and white
if ALARM IN 4 is supplied.
OFF: The camera ignores alarm inputs.
Note: If two or more alarm inputs are received while the camera is moving to a preset position, the
camera starts to aim at preset positions in small preset numerical order after current positioning.
CNT-CLS 1-2 (Output)
Two contact closure signals (Open collector type) are output through the ALARM OUT connector.
1. Move the cursor to CNT-CLS 1, then select OFF, ALARM or AUX 1 by moving the joystick to the right
or left.
When ALARM is selected, TIME OUT appears. Select an appropriate duration from among 100 MS,
200 MS, 1000 MS (1 s), 2000 MS (2 s), 4000 MS (4 s) by moving the joystick to the right or left.
Note: The shorter the duration, the more frequent will be the detection output.
2. Move the cursor to CNT-CLS 2, then select OFF, B/W or AUX 2 by moving the joystick to the right or
left.
OFF: Contact closure signals are inactivated.
ALM: Available for CNT-CLS 1 only. Motion detection is output.
AUX 1(2): An alarm signal is output when the camera receives a command from the controller.
B/W: Available for CNT-CLS 2 only. ON (active) is output when the camera operates in black and
white mode if ALARM IN 4 is set to B/W.
Note: We recommend that you set the connected external device to ignore the shorter alarm outputs
of 90 ms or less from the camera.
COAXIAL ALARM OUT
Alarm output signals are supplied through the coaxial cable.
1. Move the cursor to COAX and select ON or OFF.
31
SPECIAL 1 menu
** SPECIAL 1 **
PRIVACY ZONE
OFF(ENB)
PROPO.P/T
ON
AREA TITLE
ON(USER)
PATROL
STOP
ALARM IN/OUT
PASSWORD LOCK
OFF
CLEANING
OFF
EL-ZOOM
ON
PRESET ALM
OFF
IMAGE HOLD
OFF
RET
ALARM I/O submenu
** ALARM IN/OUT **
ALARM IN 1
OFF
ALARM IN 2
OFF
ALARM IN 3
OFF
ALARM IN 4
OFF
CNT-CLS 1
OFF
TIME OUT
100MS
CNT-CLS 2
OFF
COAX ALM OUT
OFF
RET