iCharger 4010DUO User Manual page 17

Hide thumbs Also See for 4010DUO:
Table of Contents

Advertisement

iCharger
iCharger
Synchronous
Synchronous
iCharger
iCharger Synchronous
Synchronous Balance
■ ■ ■ ■
NiXX
NiXX
NiXX
NiXX Battery
Battery
Battery
Battery Charge/Discharge
Charge/Discharge
Charge/Discharge Setup
Charge/Discharge
After adding program, it will switch to NiXX battery in Type option on the MEMORY SETUP interface, and set the
capacity, the number of cells for NiXX battery cannot be set, and the charger sets Auto by default, after editing all
parameters for program, click"
As shown in above picture, the program of NiMH, NiCd have: Charge, Discharge and Cycle .
① NiXX
NiXX
NiXX
Battery
Battery
Charge
Charge
NiXX Battery
Battery Charge
Charge Setup
Select Program→Charge to enter Charge setup interface.
Note: Charge Mode has Normal, Reflex two modes available; use the reflex mode to charge battery
can reduce heat of battery; please see charging principle in Page32 Important
" to enter NiXX CHARGE OPTION SETUP interface, after setting click "
Click "
previous interface.
Note: Tick Allow 0V Charging to allow charge with 0V.
Allow 0V Charging suits for some applications (such as charge the battery pack in the
transmitter, the circuit in series with a diode).
Tick Trickle Enable→Enable to active trickle charge and set the parameters, after setting click"
previous interface.
Note: Tick Enable to active trickle charge.
Trickle charge is based on a smaller current to charge the battery for a period, to reduce
battery consumption and extend battery usage time.
Balance
Balance
Charger/Discharger
Charger/Discharger
Balance Charger/Discharger
Charger/Discharger
Setup
Setup
Setup
" to save and return to the previous interface.
Setup
Setup
Setup
NiXX Battery Charge Setup
Chg Current:
Chg Mode:
Normal (default), Reflex
NiXX Battery Charge Advanced Setup
1mV-20mV; default: 3mV
Sensitivity:
Delay time:
0Min-20Min; default: 3Min
NiXX Battery Trickle Charge Setup
Trickle current:
Trickle timeout:
- 17 -
0.05A-40A; default: 2A
Important Notes
Important
Important
" to return to the
" to return to the
0.02A-1A; default: 0.05A
1Min-999Min;
default: 5Min