Functions
1.6
Sleep Operation
When the Sleep Operation is set, the Sleep Operation circuit activates.
The Sleep Operation circuit maintains the airflow setting made by users.
The Sleep
Operation Circuit
20
When the unit is operating under cooling mode, the set temperature is increased by 0.5°C
after the first half an hour, 1°C after the second half an hour and total of 2°C after the
following 1 hour. This function will prevent excessive cooling during summer season.
When the unit is operating under heating mode, the set temperature is decreased by 1°C
after the first half an hour, 2°C after the second half an hour and total of 3°C after the
following 1 hour. This function will prevent night sweat during summer season.
This function is available under COOL, HEAT and AUTO mode.
+2
+1
+0.5
0.5
1
2
3
set temperature (cooling mode)
1
2
set temperature (heating mode)
SiBE01-829
passed time (hour)
(R8495)