Daikin RY35GXV1 Service Manual page 84

Hide thumbs Also See for RY35GXV1:
Table of Contents

Advertisement

SiBE01-829
Step
5
Disconnect the wire
harnesses with pliers.
2. Removing the display
PCB
1
Lift the lower part of the
display PCB to remove.
2
Disconnect the
connector [CN_MB]
from the display PCB.
The figure shows the
3
names of the display
PCB component parts.
Removal Procedure
Procedure
TIMER lamp
ON/OFF switch
(R8606)
Preparation
Remove the electrical box
according to the "Removal
of Electrical Box".
(R8607)
[CN_MB]
Signal receiver
Operation lamp
(R8608)
Indoor Unit
Points
73

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents