Daikin FTY35GXV1 Installation Manual
Hide thumbs Also See for FTY35GXV1:

Advertisement

Quick Links

00_CV_3P211822-2C.fm Page 1 Tuesday, November 27, 2007 6:24 PM
INSTALLATION
MANUAL
R22 Split Series
Models
FTY25GXV1
FTY35GXV1
Installation manual
R22 Split series
Рóêоводство по монтажó
Серия R22 с раздельной óстановêой
English
Рóссêий

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FTY35GXV1

  • Page 1 00_CV_3P211822-2C.fm Page 1 Tuesday, November 27, 2007 6:24 PM INSTALLATION MANUAL R22 Split Series Installation manual English R22 Split series Рóêоводство по монтажó Рóссêий Серия R22 с раздельной óстановêой Models FTY25GXV1 FTY35GXV1...
  • Page 2: Safety Precautions

    01_EN_3P211822-2C.fm Page 1 Tuesday, November 27, 2007 6:31 PM Safety Precautions • Read these Safety Precautions carefully to ensure correct installation. • This manual classifies the precautions into WARNING and CAUTION. Be sure to follow all the precautions below: they are all important for ensuring safety. WARNING....Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
  • Page 3: Choosing A Site

    01_EN_3P211822-2C.fm Page 2 Tuesday, November 27, 2007 6:31 PM Accessories – Outdoor unit ndoor unit Mounting plate Remote controller holder Thermistor cable (8m)*1 AAA dry-cell batteries Operation manual Air-Purifying Filter with bacteriostatic, virustatic function Installation manual Indoor unit fixing screw M4 ×...
  • Page 4: Indoor/Outdoor Unit Installation Drawings

    01_EN_3P211822-2C.fm Page 3 Tuesday, November 27, 2007 6:31 PM Indoor/Outdoor Unit Installation Drawings A Mounting plate How to attach the indoor unit. A Mounting Hook the claws of the bottom frame plate to the mounting plate. If the claws are difficult to hook, remove the front grille.
  • Page 5: Outdoor Unit Installation Guidelines

    01_EN_3P211822-2C.fm Page 4 Tuesday, November 27, 2007 6:31 PM Outdoor Unit Installation Guidelines • Where a wall or other obstacle is in the path of outdoor unit’s intake or exhaust airflow, follow the installation guidelines below. Wall facing one side Walls facing two sides More than 50 More than 100...
  • Page 6: Indoor Unit

    01_EN_3P211822-2C.fm Page 5 Tuesday, November 27, 2007 6:31 PM Indoor Unit Installing the mounting plate. • The mounting plate should be installed on a wall which can support the weight of the indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall.
  • Page 7: Installing Indoor Unit

    01_EN_3P211822-2C.fm Page 6 Tuesday, November 27, 2007 6:31 PM Indoor Unit Installing indoor unit. 3-1. Right-side, right-back, or right-bottom piping. 1) Attach the drain hose to the underside of the refrigerant pipes with adhesive vinyl tape. 2) Wrap the refrigerant pipes and drain hose together with insulation tape.
  • Page 8 01_EN_3P211822-2C.fm Page 7 Tuesday, November 27, 2007 6:31 PM Note: 1) Wrap the refrigerant pipes and drain hose together with insulation tape as right figure, in case of setting the drain hose through the back of the Mounting indoor unit. Drain hose plate 2) If it difficult to fix the claws of the bottom frame on the catches of the...
  • Page 9: Drain Piping

    01_EN_3P211822-2C.fm Page 8 Tuesday, November 27, 2007 6:31 PM Indoor Unit Drain piping. The drain hose should be inclined downward. 1) Connect the drain hose, as described right. No trap is permitted. Do not put the end of the hose in water. 2) Remove the air filters and pour some water into the drain pan to check the water flows smoothly.
  • Page 10: Installing Outdoor Unit

    01_EN_3P211822-2C.fm Page 9 Tuesday, November 27, 2007 6:31 PM Outdoor Unit Installing outdoor unit. • For outdoor unit installation, see Choosing a Site and Indoor/Outdoor Unit Installation Drawings. Outdoor unit Flaring the pipe end. (Cut exactly at 1) Cut the pipe end with a pipe cutter. right angles.) Remove burrs 2) Remove burrs with the cut surface facing downward so that the...
  • Page 11: Purging Air And Checking Gas Leakage

    01_EN_3P211822-2C.fm Page 10 Tuesday, November 27, 2007 6:31 PM Outdoor Unit Purging air and checking gas leakage. • When piping work is completed, it is necessary to purge the air and check for gas leakage. WARNING 1) Do not mix any substance other than the specified refrigerant (R22) into the refrigeration cycle. 2) When refrigerant gas leaks occur, ventilate the room as soon and as much as possible.
  • Page 12: Pump Down Operation

    01_EN_3P211822-2C.fm Page 11 Tuesday, November 27, 2007 6:31 PM Pump down operation. In order to protect the environment, be sure to pump down when relocating or disposing of the unit. 1) Remove the valve cap from liquid stop valve and gas stop valve. 2) Carry out forced cooling operation.
  • Page 13: Drain Work

    01_EN_3P211822-2C.fm Page 12 Tuesday, November 27, 2007 6:31 PM Outdoor Unit Observe the notes mentioned below when wiring to the terminal block. Precautions to be taken for power supply wiring. Round crimp-style (Use a round crimp-style terminal for connection to the terminal block. terminal In case it cannot be used due to unavoidable reasons, be sure to Stranded wire...
  • Page 14: Trial Operation And Testing

    01_EN_3P211822-2C.fm Page 13 Tuesday, November 27, 2007 6:31 PM Trial Operation and Testing Trial operation and testing. 1-1 Measure the supply voltage and make sure that it falls in the specified range. 1-2 Trial operation should be carried out in either cooling or heating mode. •...