Indoor Unit
Step
4
Disconnect the three
connectors.
To remove the control
5
PCB, unfasten the 2
hooks at the upper part
from the rear side.
Lift up the upper part of
6
the control PCB, and
remove.
The figures show the
7
names of the control
PCB component parts.
74
Procedure
[CN_ODCOIL]
[CN_DISP]
[CN_TBTF]
[CN_
DISP]
[CN_FANFB]
[CN_FAN]
[CN_STP]
[CN_DISP]:
To display PCB
[CN_ODCOIL]:
To outdoor unit thermistor
[CN_TBTF]:
To terminal fuse
(R8609)
(R8610)
(R8611)
[CN_STP] To swing motor
[CN_DISP] To display PCB
[CN_FANFB], [CN_FAN] To fan
motor
FUSE 1
(3.15 A /
250 V)
(R8612)
SiBE01-829
Points
Removal Procedure