Commissioning (RF models only)

To tune the RX receiver to the frequency of the thermostat signal,
follow steps 1-5 below.
Step 1
TP5000-RF
Reset the unit by pressing and holding
-, +, V and
Step 2
Press and hold V and +
buttons for 3 seconds
(TP5000 now transmits
unique signal continuously
for 5 minutes)
Step 3
RX1
Press and hold buttons
PROG and CH1 for
3 seconds until green light
fl ashes once.
Step 4
RX2 (if applicable)
Stat 1 - perform steps 1-3
Stat 2 - wait 5 mins, perform steps 1-2 and then
RX3 (if applicable)
Stat 1 - perform steps 1-3
Stat 2 - wait 5 mins, perform steps 1-2 and then
Stat 3 - wait 5 mins, perform steps 1-2 and then
Step 5
TP5000-RF
Press V or
revert back to operating mode.
6
together until display goes blank.
press PROG and CH2 on RX2
press PROG and CH2 on RX3
press PROG and CH3 on RX3
to select temperature - the unit will