Receiver Wiring (Rf Models); Commissioning (Rf Versions Only) - Danfoss TP7000 Series Installation Manual

Electronic 7 day programmable room thermostat
Hide thumbs Also See for TP7000 Series:

Advertisement

www.boilersp.ru
Москва, ул. Народного Ополчения, д. 34, стр. 3
3.4 Receiver Wiring (RF models only)
RX1
ELECTRONICS
N L
1 2 3 4
COM
Note:
1) For mains voltage operated systems link terminal 2 to mains live supply.
2) Power supply to unit must not be switched by timeswitch.

3.5 Commissioning (RF versions only)

If the thermostat and the receiver have been supplied together
in a combined pack, the units have been paired in the factory
and no commissioning is required (RX1 only).
To tune the RX receiver to the frequency of the thermostat signal, follow
steps 1-5 below.
1. TP7000-RF
Press the recessed RESET button, using a non-
metallic object, to reset the unit.
2. Press & hold the recessed LEARN button for 3
seconds, using a non-metallic object.
NOTE: Thermostat now transmits continuously for 5 mins.
3. RX1 - Press and hold buttons PROG and CH1
for 3 seconds until green light fl ashes once.
4. RX2 (if applicable)
Stat 1 - perform steps 1-3.
Stat 2 - wait 5 mins, perform steps1-2 and then press PROG and CH2
on RX2.
RX3 (if applicable)
Stat 1 - perform steps 1 – 3.
Stat 2 - wait 5 mins, perform steps 1-2 and then press PROG and CH2
on RX3.
Stat 3 - wait 5 mins, perform steps 1-2 and then press PROG and CH3
on RX3.
5. TP7000-RF - Press
to normal operation.
Danfoss Heating
RX2 & RX3
ELECTRONICS
A
B C 1 2 3 4 5 6
ZONE
ZONE
N
1 ON
1 OFF
or
to return the unit
L
COM
ZONE
ZONE
ZONE
1 ON
1 OFF
2 ON
(499) 519-03-69
TERMINAL 6
RX3 ONLY
ZONE
GB
3 ON
F
D
ES
DK
RESET
NL
I
LEARN
GR
PL
RX1
LT
CZ
HR
RO
7