3.2.2
Control panel DIEMATIC 3
General ON
/ OFF
1
2
Reset button + Alarm indicator
Switch AUTO/
3
4
TEST STB button
1
Text and numerical display
2
Graphic display bar for the programme in circuit A, B or C
Light area: Reduced temperature heating period or tank load
3
disabled
Dark area: Comfort temperature heating period or tank load
4
enabled
5
Flashing cursor showing the current time
Number display (current time, adjusted values, parameters,
6
etc.)
Active programme display, P1, P2, P3, P4
7
or
E: Summer mode activated
The arrows flash when setting values can be modified using
8
the + and - keys
20/02/09 - 300004565-001-C
Electromechanical components
switch
5
Safety thermostat with manual reset (110 °C)
6
Timed circuit breaker (4 A)
7
Operating light
Display
9
Circuit operation symbols
Opening the 3-way valve
Closing the 3-way valve
Displayed circuit pump on
A, B, C Name of the circuit displayed
10
Symbol displayed above the active operating mode
Symbols indicating that the following inputs/outputs are
11
active
Burner on
DHW load pump on
Summer mode
Not available
DTG 130
3. Description