Toshiba G9000 SERIES Installation And Operation Manual page 69

480/480 v 100/160/225 kva
Hide thumbs Also See for G9000 SERIES:
Table of Contents

Advertisement

Note 3
Code
Status
indication
message
INVERTER
UF201
OVERVOLTAGE
INVERTER
UF202
UNDERVOLTAGE
INVERTER
UF203
OVERCURRENT
OUTPUT CIRCUIT
UF204
ABNORMAL
UPS CONTROL
UF206
CIRCUIT ERROR
ZERO PHASE
UF207
OVERCURRENT
UPS CONTROL
UF208
CIRCUIT ERROR
UF209
52C ABNORMAL
UF210
52C ABNORMAL
UF211
52C ABNORMAL
UF213
OVERTEMP
COOLING FAN
UF214
ABNORMAL
INVERTER
UF217
OVERVOLTAGE
ZERO PHASE
UF230
OVERCURRENT
UPS CONTROL
UF253
CIRCUIT ERROR
OUTPUT VOLTAGE
UF256
ABNORMAL
UF257
52C ABNORMAL
UF258
LOAD ABNORMAL
ANOTHER UPS
UF259
ABNORMAL
G9000 Enhanced Series UPS Installation and Operation Manual – 93823-004
Table 7–1 Fault Codes (Cont.)
Meaning
Detection of output overvoltage.
Output voltage dropped.below specs.
Detection of inverter overcurrent.
Detection of a large variation of the reference
error signal (current reference and actual
current).
Discrepancy between output voltage and
external voltage (bypass, common ac bus)
Inverter zero-sequence overcurrent.
Cross current is abnormal.
Error to close the contactor 52C.
Error to open the contactor 52C.
No answer from contactor 52C during inverter
operation.
Heatsinks temperature exceeds thermal
settings.
Thermal relay activated protection.
Detection of inverter output phase overvoltage.
Detection of zero-sequence overcurrent.
Discrepancy between output voltage and
inverter voltage, or between output voltage
and bypass voltage.
Output voltage is outside of the specified
range.
Contactor 52C failed to open during load
transfer from inverter to bypass.
Load transfer due to overload for over 4 times
within 5 minutes.
No detection of another UPS voltage signal.
Guidance
Buzzer
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Continuous
ENGINEER
sound
CALL SERVICE
Intermittent
ENGINEER
sound
CALL SERVICE
Intermittent
ENGINEER
sound
CALL SERVICE
Intermittent
ENGINEER
sound
CALL SERVICE
Intermittent
ENGINEER
sound
CALL SERVICE
Intermittent
ENGINEER
sound
Note 1
Note 2
External
Failure
relay contact
lamp
Major
Lit on
Major
Lit on
Major
Lit on
Major
Lit on
Major
Lit on
Major
Lit on
Major
Lit on
Major
Lit on
Major
Lit on
Major
Lit on
Major
Lit on
Major
Lit on
Major
Lit on
Major
Lit on
Minor
Flicker
Minor
Flicker
Minor
Flicker
Minor
Flicker
Minor
Flicker
59

Advertisement

Table of Contents
loading

Table of Contents