Vitocomfort 200; Wireless Base Station - Viessmann VITODENS 222-F Technical Manual

Gas condensing storage combi boiler
Table of Contents

Advertisement

Control units
(cont.)
1 4
3
Vitotrol 300-RF
9 0
2 3
Wall mounting bracket

Vitocomfort 200

Part no. Z013 768
KM BUS subscriber or wireless subscriber
The Vitocomfort 200 combines heating and photovoltaics for integra-
ted energy management, supplemented by shade, light and security
functions to create a complete smart home system.
The Vitocomfort 200 is suitable for use in any application area.
■ The automated individual room controls regulate room tempera-
tures according to demand and reduce energy consumption.
6
■ The system is self-learning with regard to building engineering
physics, resulting in optimised flow temperatures and cost savings.
■ DHW heating can be automated with time programs as required
and can be requested directly as needed.
■ A display of solar yield ensures optimum transparency and gives
the user an insight into the energy flows.
■ An automatic "open window detected" function saves energy costs
when windows/doors are open.
■ Suitable for radiators and underfloor heating systems
■ Display of boiler messages
For further information, see the "Vitocomfort 200" technical guide.

Wireless base station

Part no. Z011 413
KM BUS subscriber
For communication between the Vitotronic control unit and the fol-
lowing wireless components:
■ Wireless remote control Vitotrol 200-RF
■ Wireless remote control Vitotrol 300-RF
■ Wireless outside temperature sensor
■ Vitocomfort 200 control centre
VIESMANN
80
2 2
Specification
Power supply via power
230 V~/4 V
supply unit for installation
in a plaster box
Power consumption
2.4 W
Radio frequency
868 MHz
Wireless range
See "Wireless accessories" technical
guide
Protection class
II
IP rating
IP 30 to EN 60529; ensure through de-
sign/installation
Permissible ambient temperature
– Operation
0 to +40 °C
– Storage and transport
−25 to +60°C
Setting range for set room
temperature
3 to 37 °C
3 4
For up to 3 wireless remote control units or 3 Vitocomfort 200 control
centres. Not in conjunction with a hardwired remote control unit.
Connection:
■ 2-core lead, length up to 50 m (even when connecting several KM
BUS subscribers).
■ Never route this cable immediately next to 230/400 V cables.
VITODENS

Advertisement

Table of Contents
loading