Viessmann VITODENS 222-F Technical Manual page 53

Gas condensing storage combi boiler
Table of Contents

Advertisement

Design information
Assembly kit with mixer for installation on finished walls, part no. Z009 891
440
330
220
50
55
A
BCD
E
F G
H
K
BCD
E
F G
H
K
A
L
A Heating flow, heating circuit with mixer R ¾
B Solar return R ¾/Ø 22 mm
C Heating flow, heating circuit without mixer R ¾
D DHW R ½
E DHW circulation R ½ (separate accessory)
F Gas connection R ½
G Cold water R ½
H Heating return, heating circuit without mixer R ¾
K Solar flow R ¾/Ø 22 mm
L Heating return, heating circuit with mixer R ¾
Note
The adjustable feet give the height measurements of the connec-
tions a tolerance of + 7 mm.
For connecting the on-site gas, heating water and DHW lines from
above.
VITODENS
(cont.)
L
Assembly kit comprising:
■ Plate heat exchanger for system separation of the heating circuit
with mixer
■ Variable speed high efficiency circulation pump for the heating cir-
cuit with mixer
■ 3-way mixer with mixer motor
■ Mixer PCB, capable of communicating with Vitotronic 200 via KM
BUS
■ Adjustable bypass
■ Connection set for installation on finished or unfinished walls, with:
– Connection pipes
– Shut-off valves for heating water flow and return, with boiler
drain & fill valve
– 2 connectors for DHW
– 2 connectors for solar flow and return
– Gas shut-off valve with thermally activated safety shut-off valve
■ Flow temperature sensor
5
VIESMANN
53

Advertisement

Table of Contents
loading