Control units
(cont.)
– Room temperature
– Outside temperature
– Operating condition
– Graphic illustration of solar yield in conjunction with the solar
control module, type SM1
– Wireless signal reception quality
■ Settings:
– Set room temperature for standard mode (normal room tempera-
ture) and reduced mode (reduced room temperature)
– Set DHW temperature
– Operating program, switching times for heating circuits, DHW
heating and DHW circulation pump plus further settings via plain
text menu on the display
– Party and economy mode can be enabled via keys
■ Integral room temperature sensor
Note
Observe the "Wireless accessories" technical guide.
Standard delivery:
■ Vitotrol 300-RF
■ Table-top dock
■ Plug-in power supply unit
■ 2 rechargeable NiMH batteries for operating outside the table-top
dock
1 4
3
Vitotrol 300-RF

Vitotrol 300-RF with wall mounting bracket

Part no. Z011 412
Wireless subscriber
■ Displays:
– Room temperature
– Outside temperature
– Operating condition
– Graphic illustration of solar yield in conjunction with the solar
control module, type SM1
– Wireless signal reception quality
■ Settings:
– Set room temperature for standard mode (normal room tempera-
ture) and reduced mode (reduced room temperature)
– Set DHW temperature
– Operating program, switching times for heating circuits, DHW
heating and DHW circulation pump plus further settings via plain
text menu on the display
– Party and economy mode can be enabled via the menu
■ Integral room temperature sensor for room temperature hook-up
(only for one heating circuit with mixer)
VITODENS
2 2
1 4
0
5 0
Table-top dock
Specification
Power supply via plug-in
230 V~/5 V−
power supply unit
Power consumption
2.4 W
Radio frequency
868 MHz
Wireless range
See "Wireless accessories" technical
guide
Protection class
II
IP rating
IP 30 to EN 60529; ensure through de-
sign/installation
Permissible ambient temperature
– Operation
0 to +40 °C
– Storage and transport
−25 to +60°C
Setting range for set room
temperature
3 to 37 °C
Installation location:
■ Weather-compensated mode:
installation anywhere in the building
■ Room temperature hook-up:
the integral room temperature sensor captures the actual room
temperature and effects any necessary correction of the flow tem-
perature.
The captured room temperature depends on the installation site:
– Main living room on an internal wall opposite radiators
– Not on shelves or in recesses
– Never in the immediate vicinity of doors or close to heat sources
(e.g. direct insolation, fireplace, TV set, etc.).
Note
Observe the "Wireless accessories" technical guide.
Standard delivery:
■ Vitotrol 300-RF
■ Wall mounting bracket
■ Power supply unit for fitting into a plaster box
■ 2 rechargeable NiMH batteries for use out of wall mounting
bracket