Vitotrol 300 Rf With Wall Mounting Bracket; Vitocomfort 200 - Viessmann VITODENS 242-F Technical Manual

Gas condensing storage combi boiler
Table of Contents

Advertisement

Control units
(cont.)

Vitotrol 300 RF with wall mounting bracket

Part no. Z011 412
Wireless subscriber
■ Indicators:
– Room temperature
– Outside temperature
– Operating condition
– Graphic illustration of solar yield in conjunction with the solar con-
trol module, type SM1
– Wireless signal reception quality
■ Settings:
– Set room temperature for standard mode (normal room tempera-
ture) and reduced mode (reduced room temperature)
– Set DHW temperature
– Operating program, switching times for heating circuits, DHW
heating and DHW circulation pump plus further settings via plain
text menu on the display
– Party and economy mode can be enabled via the menu
■ Integral room temperature sensor for room temperature hook-up
(only for one heating circuit with mixer)
Installation site:
■ Weather-compensated mode:
Installation anywhere in the building
■ Room temperature hook-up:
The integral room temperature sensor captures the actual room
temperature and effects any necessary correction of the flow tem-
perature.
The captured room temperature depends on the installation site:
– Main living room on an internal wall opposite radiators
– Not on shelves or in recesses
– Never in the immediate vicinity of doors or close to heat sources
(e.g. direct sunlight, fireplace, TV set, etc.)
Note
Observe the "Wireless accessories" technical guide.
Standard delivery:
■ Vitotrol 300 RF
■ Wall mounting bracket
■ Power supply unit for fitting into a plaster box
■ 2 rechargeable NiMH batteries for operating outside the wall mount-
ing bracket
7
1 4
3
Vitotrol 300 RF

Vitocomfort 200

Part no. 7172 642
Wireless domestic control centre with mains power operation for reg-
ulating single rooms.
VIESMANN
94
2 2
9 0
2 3
Wall mounting bracket
Specification
Power supply via power supply unit for
installation in a plaster box
Power consumption
Radio frequency
Wireless range
Safety category
IP rating
Permissible ambient temperature
– Operation
– Storage and transport
Setting range for set room temperature
■ Optimum room ambience by means of regulating the temperature
and relative humidity in combination with a commercially available
humidifier or dehumidifier
■ Saving heating and power costs
230 V~/4 V
2.4 W
868 MHz
See "Wireless accesso-
ries" technical guide
II
IP 30 to EN 60529; ensure
through design/installation
0 to +40 °C
−25 to +60 °C
3 to 37 °C
VITODENS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 333-fVitodens 222-f

Table of Contents