CUT THE PUMP BANDING STRAPS

CUT THE PUMP BANDING STRAPS
IMPORTANT! This step is necessary to make your
Kohler whirlpool operate more quietly.
·
Use tin snips to cut the two pump banding straps
from each whirlpool pump.
NOTE:
Do not raise the pumps higher than they were
before you cut the pump banding straps. If the pumps
are raised too high, they will not prime properly. Make
sure the rubber isolation feet are in place.
·
To minimize whirlpool noise and vibration, be sure
the pumps are not in direct contact with the
whirlpool after the pump banding straps are cut. The
pump controls contain rubber isolation feet to
reduce pump noise.

INSTALL THE PLUMBING

INSTALL THE PLUMBING
CAUTION: Risk of property damage.
watertight seal on the whirlpool drain.
·
Connect the drain to the trap according to the drain
manufacturer s instructions.
'
NOTICE:
An access panel will simplify future
maintenance.
NOTE:
Check for the required clearance under the rim
of the bath before drilling the hole for the faucet.
·
Install the faucet valving according to the
manufacturer s instructions. Do not install the faucet
'
trim until instructed.
·
Open the hot and cold water supplies.
·
Check the supply connection for leakage.
·
Run water into the whirlpool, and check the drain
connections for leakage.

MAKE ELECTRICAL CONNECTIONS

MAKE ELECTRICAL CONNECTIONS
NOTE:
The product model number is printed on a label
on the pump side of the whirlpool bath. This label also
identifies the electrical rating of the product. All
whirlpools come equipped with a wiring junction box
and are designed to operate between 208 VAC and
240 VAC at either 50 Hz or 60 Hz.
WARNING: Risk of electrical shock.
sure the power has been disconnected before
performing the following procedures. Refer to the
"Important Information" section.
1141609-T01-A
Pump
Wiring Harness
Control
Rubber Isolation Feet
Cut the pump
banding straps
Ensure a
Make
·
·
Junction Box
·
·
·
·
·
208~240
7