Kohler K-1111-VLN-0 Installation Instructions Manual

Kohler K-1111-VLN-0 Installation Instructions Manual

Consonance whirlpool with bodymassage backjets

Advertisement

Quick Links

BEFORE YOU BEGIN
BEFORE YOU BEGIN
·
Please read these instructions carefully to
familiarize yourself with the required tools, materials,
and installation sequences. Follow the sections that
pertain to your particular installation. This will help
you avoid costly mistakes. In addition to proper
installation, read all operating and safety instructions.
CAUTION: Risk of product damage.
the whirlpool by the piping or pump, or use the
piping or pump for structural support of the
whirlpool.
·
We recommend this whirlpool for corner, drop-in, or
flush installations. An undermount kit is also
available.
·
Inspect the whirlpool for damage before you begin
installation.
·
You must install this whirlpool to an adequately
supported, level subfloor.
·
Confirm adequate support for a rim-mounted faucet,
if used; large faucets that may be inadvertently used
as a means of support are not appropriate or safe
for this installation.
·
Consult local and national codes.
·
Kohler Co. reserves the right to make revisions in
the design of products without notice, as specified in
the Price Book.
·
All information is based on the latest product
information available at the time of publication.
Kohler China Ltd. reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
·
These instructions contain important care, cleaning,
and warranty information-
instructions for the consumer.
1036303-T01-A
1141609-T01-A
Do not lift
please leave these
·
·
·
·
·
·
·
·
·
ã
Copyright Kohler China Ltd., 2011
C
1
INSTALLATION INSTRUCTIONS
WHIRLPOOL
K-1111-VLN
, 2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the K-1111-VLN-0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kohler K-1111-VLN-0

  • Page 1 · · Consult local and national codes. · · Kohler Co. reserves the right to make revisions in the design of products without notice, as specified in the Price Book. · · All information is based on the latest product information available at the time of publication.
  • Page 2: Product Information

    IMPORTANT INFORMATION IMPORTANT INFORMATION WARNING: When using electrical products, basic precautions should always be followed, including the following: DANGER: Risk of electric shock. Connect only to circuits protected by Ground-Fault Circuit- (GFCI) (ELCB) Interrupters (GFCI s) or Earth-Leakage Circuit- Breakers (ELCB s). WARNING: Risk of electric shock.
  • Page 3: Tools And Materials

    Kohler Co. shall not be liable under its warranty or otherwise for personal injury or damage caused by any such unauthorized modification.
  • Page 4 PREPARE THE SITE - CONCRETE CONSTRUCTION PREPARE THE SITE - CONCRETE CONSTRUCTION CAUTION: Risk of product damage. Do not support the whirlpool by the rim. NOTICE: Adequate floor support must be provided. Consult the roughing-in sheet packed with your whirlpool for specific floor loading requirements. ·...
  • Page 5: Prepare The Whirlpool

    PREPARE THE SITE - WOOD CONSTRUCTION PREPARE THE SITE - WOOD CONSTRUCTION CAUTION: Risk of product damage. Do not support the whirlpool by the rim. NOTICE: Adequate floor support must be provided. Consult the roughing-in sheet packed with your whirlpool for specific floor loading requirements. Three access panels are required.
  • Page 6 SECURE THE WHIRLPOOL TO THE SUBFLOOR SECURE THE WHIRLPOOL TO THE SUBFLOOR CAUTION: Risk of product damage. Do not lift the whirlpool by the piping or pumps, or use the piping or pumps for structural support of the whirlpool. · ·...
  • Page 7: Cut The Pump Banding Straps

    CUT THE PUMP BANDING STRAPS CUT THE PUMP BANDING STRAPS IMPORTANT! This step is necessary to make your Kohler whirlpool operate more quietly. · · Use tin snips to cut the two pump banding straps from each whirlpool pump. NOTE: Do not raise the pumps higher than they were before you cut the pump banding straps.
  • Page 8 WARNING: Risk of electrical shock. To reduce (GFCI) the risk of electrical shock, connect the pump to a properly grounded Ground-Fault Circuit- (ELCB) Interrupter (GFCI) or Earth-Leakage Circuit- 208-240 50/60 Breaker (ELCB). This will provide additional protection against line-to-ground shock hazard. A 208-240 V, 20 A, 50/60 Hz dedicated circuit is required.
  • Page 9: Install The Whirlpool Trim Kit

    INSTALL THE WHIRLPOOL TRIM KIT INSTALL THE WHIRLPOOL TRIM KIT · · Install the whirlpool trim kit according to the instructions packed with the trim kit. Pay particular attention to the jet installation steps below - they are very important and are included here to help you obtain smooth, trouble-free jet operation.
  • Page 10: Complete The Finished Wall/Deck

    · · Turn on the chromatherapy cycle and allow it to sequence through all eight colors; white, violet, indigo blue, aqua blue, green, yellow, orange and red. It takes approximately 1 minute to cycle through all eight colors. · · Verify functions using the remote controls.
  • Page 11: Clean-Up After Installation

    CLEAN-UP AFTER INSTALLATION CLEAN-UP AFTER INSTALLATION · · When cleaning up after installation, do not use abrasive cleansers, as they may scratch and dull the whirlpool surface. If necessary, use warm water and a liquid detergent to clean the surface of the whirlpool, user keypad and remote control.
  • Page 12: Confirm Proper Operation

    CONFIRM PROPER OPERATION CONFIRM PROPER OPERATION Fill the Whirlpool NOTE: Please read these steps carefully before you operate your whirlpool. · · Turn the jet trim rings fully counterclockwise. Position the jet nozzles so they face down toward the basin. ·...
  • Page 13: Modes Of Operation

    · · Rotate the outer ring until the heater button is flashing. Press OK to turn the heater off. Press " " " OK again to turn the heater back on. The heater " will help to maintain the water temperature up to 104 F (40 C).
  • Page 14: Remote Control Operation

    Effervescence Operation · · With the whirlpool operating, rotate the outer ring of the keypad until the effervescence icon is flashing. · · Press OK to activate the effervescence ports. The " " effervescence action will start at the flow volume last set in the flexjet flow mode.
  • Page 15: Troubleshooting Procedures

    TROUBLESHOOTING PROCEDURES TROUBLESHOOTING PROCEDURES This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified electrician should correct all electrical problems. For warranty service, contact your dealer or wholesale distributor. Troubleshooting the Whirlpool System...
  • Page 16 B. GFCI ELCB GFCI ELCB GFCI ELCB GFCI ELCB A. GFCI ELCB GFCI ELCB A. 20 1141609-T01-A...
  • Page 17 Troubleshooting continued SYMPTOMS PROBABLE CAUSES RECOMMENDED ACTION 10. Pump operates but A. Motor/pump does not work. A . Replace motor/pump. variable speed B. Control does not work. B. Replace control. feature does not work. 11. Bath water cools A. Allow bath water to cool. Water temperature above 104 F (40 C).
  • Page 18 Troubleshooting the Beckjet Syetem SYMPTOMS PROBABLE CAUSES RECOMMENDED ACTION 15. Backjets do not A. Whirlpool pump is not operating. A. Turn on pump. operate. B. Backjet butterfly valve does not open. B. Check for loose connections or wires C. Not enough water in whirlpool. leading from backjet pulse canister to D.
  • Page 19 Troubleshooting the Effervescence Jets SYMPTOMS PROBABLE CAUSES RECOMMENDED ACTION 17. Effervescence ports A. Whirlpool pump is not operating. A. Turn on pump. do not work. B. Effervescence butterfly valve does not B. Replace butterfly valve. work. C. Pump does not work. C.