15. Verify the unit has power by observing that the LEDs are lit or flashing.
CAUTION
For mounting with band clamps:
1. Attach the pole mount bracket section at the desired mounting location using band clamps.
2. With the angle adapter bracket section positioned so that the open connector slots are on the bottom,
attach the angle adapter bracket section to the pole mount bracket section using two 1/2 inch bolts and
nuts. Tighten the nuts to 30 inch pounds (lbf-in).
3. Position the access point bracket section so that the bottom of the section with the straight (not bevel cut)
sides is oriented toward the bottom side of the access point. Using a torque wrench or a ratchet and a
10mm socket, or an adjustable wrench, attach (but don't tighten) the access point bracket section to the
AP6562 with the with four M6 hex flange screws.
4. Insert two M6 hex flange screws into the bottom holes on the sides of the access point bracket section.
5. Insert the two M6 hex flange screws in the bottom holes on the sides of the access point bracket section
into the open slot connections on the bottom of the angle adapter bracket section.
6. Rotate the access point bracket section upward and align the top holes on the sides with the top holes on
the angle adapter bracket section. Insert two M6 hex flange screws into the top holes on the angle
adapter bracket section.
7. Use a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to finish attaching the
access point bracket section to the angle adapter bracket section with the M6 hex flange screws in the
open slot connections and the top holes on the angle adapter bracket section. Do not tighten the screws
until all rotation and tilt adjustments are complete.
8. Tighten all hex flange screws to 60 inch pounds (lbf-in).
9. If required, install and attach a Kensington security cable (customer supplied) to the unit's lock port.
10. Attach an Ethernet cable from the access point to a controller with an 802.3at-compatible power source
or use the PWRS-14000-148R power supply to supply power to the AP6562 (once fully cabled).
If not using a 802.3at capable controller to power the AP6562, ensure
only the AP6562's designated outdoor power supply
(AP-PSBIAS-7161-US or AP-PSBIAS-7161-WW) is used to supply
power to the access point. Using an incorrectly rated power supply
could damage the unit and void the product warranty. Do not actually
connect to the power source until the cabling portion of the
installation is complete.
AP6562 Access Point