10.15

Setting control signals for the cam controller

Definition
The "control signals for the cam controller" setting can be used to enable cam processing
and the tracks.
Programming steps
1. Set the required bits at the channel DB.
2. The data are transferred to the module at each call of FB CAM_CTRL.
Data used in the channel DB
Address
15.4
16.0
Effects
Cam processing will be started or stopped based on the enable status.
The track identifier bits of enabled tracks are transferred to the track signals and digital
outputs.
FM 352 electronic cam controller
Operating Instructions, 05/2011, A5E01071724-03
Name
Type
CAM_EN
BOOL
TRACK_EN
WORD
10.15 Setting control signals for the cam controller
Start value
FALSE
1 = enable cam processing
W#16#0
Enable cam tracks 0 to 12
Bit 0 = track 0
Settings
Comment
133